(Refurbished) Toshiba Canon Aquilion Prime Cardiac CT

(Refurbished) Toshiba Canon Aquilion Prime Cardiac CT

Regular price Rs. 27,299,998.00
Regular price Rs. 29,400,000.00 Sale price Rs. 27,299,998.00
Sale Sold out
Tax included. Shipping calculated at checkout.
Pre Owned Toshiba / Canon Aquilion Prime 160 slice Cardiac CT Patient accessibility improvement by 78 cm bore Gantry Aperture...
Currently there are peoples are currently looking at this product

Shipping & Returns

Enjoy fast and reliable delivery with orders typically arriving within 3–7 business days.
Returns are accepted within 7 days of delivery for eligible products that are unused and in their original condition.

Share Product

SKU:MBAASBHUDCU1BY215PJV

Categories: Surgical Equipment

Tags: medikar , Refurbished CT Scanner

View full details

Pre Owned Toshiba / Canon Aquilion Prime 160 slice Cardiac CT

  • Patient accessibility improvement by 78 cm bore Gantry Aperture Size

  • Tube: 7.5 MHU, 10-600mA range

  • Generator: 72kW

  • Rotation Time: 0.35 sec

  • Gantry Physical: ±30°

  • Detector:

  • Rows: 80

  • Slice Thickness: 0.50 mm

  • Width: 40mm

  • Low Contrast Resolution of 2mm @ 0.3% = Industry Best Resolution

  • i-station Interface

  • Ultra Fast Reconstruction

  • 2,572 views/sec high clinical detailed data.


  • Table:
  • Height Adjustable

  • 47 cm couch width – widest in industry

  • 205 kg table limit with full accuracy

  • Table lowest height of 33 cm - for the pediatric, the elderly, and the physically challenged

  • 1800 mm scan range - All regions attainable in a single set-up, essential for Trauma, Multiple regions, ICU etc.

    Spatial Resolution:
  • 21.5 lp/cm at MTF 0%
  • 14.5 lp/cm at MTF 2%
  • 8.0 lp/cm at MTF 50%

*For reference


SMOOTH & EFFICIENT WORKFLOW:

Migrating the Basic Technology Developed for Aquilion ONE 640 slice CT scanner
Active Collimator (up to 20% dose reduction)


  • The active collimator eliminates X-rays that are not used for image reconstruction in helical scanning.
  • The collimator operates automatically at the start and end of scan range limiting the extend of X-ray beam, permitting further dose reduction.
  • With active collimation the exposure can be reduced by up to 20%.

AIDR (Adaptive Iterative Dose Reduction) (up to 75% dose reduction, HQ Image)

  • AIDR is an image reconstruction algorithm that allows high image quality to be achieved at a low exposure dose.

  • Noise components are selectively extracted from signal in an iterative process improving image quality.

  • With AIDR the exposure can be reduced by up to 75% maintaining superb image quality.

TOSHIBA’s Unique SEMAR

Single Energy Metal Artifact Reduction

Ideal for Imaging of:

  • Cardiac CT scanning

  • Brain Perfusion scans

  • Long Length Angios

  • Chest scans in less than 10 seconds, less breath hold

  • Fast Trauma scans

  • Excellent 3D images

Country of Origin: Japan

US-FDA Approval: Yes

No content available